Cold-formed steel design, explained
How thin-walled steel members buckle, how AISI S100-24 turns that into strength, and how to check real studs, joists, columns and purlins. Every number in these articles is computed by the ColdCalc engine, the same one the calculator runs.
New to cold-formed steel? Start here
Cold-formed steel design: a practical guide to AISI S100-24
How cold-formed steel studs, joists, columns and purlins are designed to AISI S100-24: buckling modes, DSM and EWM, load combinations, the checks that govern, and where to start.
How to read an SSMA stud designation: 600S162-54 explained
What each part of an SSMA designation like 600S162-54 means: depth, style, flange width and mils, with design thicknesses, lip lengths, bend radii and the section's properties.
Local, distortional and global buckling of cold-formed steel, explained
The three ways a thin-walled steel member buckles, how to tell them apart on a signature curve, and how AISI S100-24 turns each into a strength. With finite strip results for a real stud.
Beginner
Cold-formed steel floor joist spans: a span table and what limits it
How far a steel floor joist spans, and why: bending, shear, web crippling and deflection to AISI S100-24, a worked joist, and a span table computed for 12, 16 and 24 in. spacing.
Steel stud limiting heights: what sets them, with a height table
What a limiting height is, how strength and deflection (L/240, L/360, L/600) set it, the assumptions behind any table, and wall stud heights computed to AISI S100-24 for wind.
Cold-formed steel design software in 2026: an honest comparison
CFS, CUFSM, ClearCalcs, SkyCiv, Simpson CFS Designer, THIN-WALL-2 and ColdCalc: what each does, which edition of AISI S100 it checks, where it runs and what it costs.
Intermediate
The Direct Strength Method in AISI S100-24, with a worked example
The S100-24 Direct Strength Method step by step: elastic buckling loads, slenderness, the new rational strength equations, and a full column example with every number shown.
Cold-formed steel wall stud design example (AISI S100-24, LRFD)
A complete wind-bearing wall stud check to AISI S100-24 and ASCE 7-22: combinations, axial, bending, P-δ, H1.2, shear and deflection, every number computed.
Effective Width Method vs Direct Strength Method: when they differ, and why
How the two AISI S100 methods model local and distortional buckling, where their answers diverge for studs and tracks, and how to choose between them.
What changed in AISI S100-24: a guide for designers
The changes in the 2024 North American Specification that affect everyday member design: new DSM equations, flexure up to Mp, shear, torsion and bimoment, and how much answers move.
Web crippling of cold-formed steel joists and purlins (S100-24 §G5)
Why thin webs crush at supports and under point loads, the four load cases, how bearing length and fastening change the strength, and the H3 check with bending.
Screw connections in cold-formed steel: shear, pull-out and pull-over (S100-24 §J4)
How to design self-drilling screw connections to AISI S100-24: tilting and bearing, pull-out, pull-over, spacing and combined shear and tension, with a worked example and strength tables.
Advanced
The finite strip method and the signature curve: what CUFSM computes, and how to read it
How the finite strip method finds a section's buckling loads, what the signature curve and cFSM modal identification show, and how the results feed the Direct Strength Method.
Designing lapped Z-purlins: laps, anti-roll bracing and the R factor
How continuous lapped Z-purlins carry load, where they are checked, what anti-roll bracing does, and how the I6.2.1 R factor sets uplift strength for through-fastened roofs.
Gross and effective properties, buckling loads and strengths for every stud and track.
Find a section